GUANGDONG SHANAN TECHNOLOGY CO.,LTD

GUANGDONG SHANAN TECHNOLOGY CO.,LTD

Manufacturer from China
Verified Supplier
8 Years
Home / Products / X Ray Inspection System /

1000 * 1000mm X Ray Luggage Scanner 200kg Load With Two Operation Table

Contact Now
GUANGDONG SHANAN TECHNOLOGY CO.,LTD
Visit Website
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MrLeon Lin
Contact Now

1000 * 1000mm X Ray Luggage Scanner 200kg Load With Two Operation Table

Ask Latest Price
Video Channel
Brand Name :SHANAN
Model Number :VX100100D
Certification :CE, ISO
Place of Origin :CHINA
MOQ :1 set
Price :negotiation
Payment Terms :T/T
Supply Ability :100 set/month
Packaging Details :Box
Tunnel size :1000*1000mm
Application :x ray screening and detection
Load ability :200KG
x ray penetration :34mm stailness steel
OEM :accept
operation table :two
screen :black and colorful
Anode Voltag :100-160KV
power consume :1.5 KW (Max)
image storage :Storage 60000 pictures in real time
Delivery Time :15work days
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Quality X Ray Baggage Scanner & X Ray Inspection System x ray screening system airport x ray machine

FEATURE:


1. Alarm by sounds & light::Alarm by sounds and light when conform to condition.
2. Network interface:Could be connect local area network and support multi-terminal check baggage at same times
3. Safety ray:Transmit ray under automatic control, avoids the miss.
4. Turn off by a key control:Turn off the machine only need one step:revolves the key. The equipment automatic security close-down, does not need complex many steps, is simpler.
5. Eagle-eye:Could be expediently observing enlargement area.

6. Estimate malfunction by self:Automatic estimate malfunction and prompt message, helpful for the maintenance.

TECHNICAL DATA:

Tunnel Size: 1000(W)×1000(H)mm
Conveyor Speed: 0.22 m/s
Conveyor Max Load: 200 kg
Single inspection dosage < 1.5µGy
Wire Resolution: 0.1mm metal line
Steel Penetration: 30MM armor plate
Film Safety: For ISO 1600
Maximum leakage radiation <0.3µGY/H

X-RAY GENERATOR:
Orientation: Vertically Upward
Tube Current: 0.4~1.2MA(adjustable)
Anode Voltage: 100~160 KV(adjustable)
Angle: 80°
Generator cooling/working periods Sealed oil bath with forced air/100%


IMAGE PERFORMANCE SYSTEM:


X-ray Sensor: L Type Photo-Diode array detector 12bit.

Monitor: High resolution 17inch color D display.

Color Quality: 24 Bit real colors.

Edge Enhancement: Object contour edge is more distinct.

Super Image Enhancement: Image detail is more distinct.

High penetrate strength display: Increase brightness of dark area in image to display object which is behind high absorptivity mass distinctly.

Low Penetrate strength Display: increase contrast of low absorptivity mass (easy to penetrate) to display it distinctly.

Magnifier: Function of partial enlargement

Brightness/Dimming: Increase brightness of image/decrease brightness of image.

Image recurrence: Display previous twenty image and process any one of them.

Image restoration: Restore image to initial status at the time of stopping conveyor

Image storing: Real Time store any image and process it in operation status.

1000 * 1000mm X Ray Luggage Scanner 200kg Load With Two Operation Table
MULTI-ENERGY FUNCTION:

Multi-energy color: Display organic material for orange, display inorganic material for blue, and display mixture for green.

High energy / low energy: switch to display two energy type, high energy stands for metal etc. low energy stands for nonmetallic.

Auxiliay function for drugs & explosives: Help to detect such dangerous material as drugs& explosives etc.

Audible & visible alarm: Give sound and visible signal when conforming to condition.

ETHERNET TCP/IP FUNCTION

OPERATING ENVIRONMENT:

Storage Temperature: -20ºC to 60ºC
Operating Temperature: 0ºC to 45ºC
Relative Humidity: 20 to 95% non-condensing
System Power: 220 VAC (±10%) 50±3HZ
Power wastage: 1.5 KW (Max)
Noise: <65DB

Tunnel Size:

1000(W)*1000(H)mm
Conveyor Speed: 0.22m/s
Conveyor Max Load: 200kgs
Dose per Inspection: <1.7μGy/h
Resolution: <0.101mm Metal Wire
Penetration: 34mm Steel
Film Safety: Guarantee ISO1600 Film
X-ray Leakage: <0.1μGy/h (at a distance of 5cm From external housing)
Generate direct: downward
Generate angle: 80 degree
Anode Voltage: 100-160Kv
Anode power: 0.4 to 1.2mA
Cooling / Duty Cycle: Oil Cooling /100%
X-ray Sensor: L-Shaped Photodiode Array (mono-energetic), 12bit Deep
Monitor: High Resolution Color, D Accord, 17 inch
Image Processing:

Edge enhancement, image strengthening, image lightening,

reducing darkening, image returning, image retrieval.

Image Grey Level: 4096
Image Max Resolution: 1024 * 1280 pixel
Image Processing: 24bit for processing real time
Image storage: Storage 60000 pictures in real time
Zones & Zoom:

1-9 Image regions, 2, 4, 8, 16 Times Enlarge,

Whole screen continuous observation

Operation temperature/Humidity: 0℃-45℃/20%-95%(non-condensing)
Storage Temperature/Humidity: -20℃-60℃/20%-95%(non-condensing)
Operation Power: 220VAC(±10%)50±3Hz
Power Consumption: 1.8 KW (max), 0.3KW(working)
Noise: <58db

Applications:

Airports,

Transport terminals,

Buildings,

Factories (to find needle in clothing, shoes, bags),
Courthouses,
Embassies,
Military installations,

Prisons,
Hotels,
Schools ,

Convention centers,
Security checkpoints,

Special events location

FAQ

.

PRODUCT CLIENT’S REQUIREMENT
Tunnel Dimension 1m(W) x 1m(H0 Approx

Verify Physically

Measure through measuring tape or a baggage of this dimension should be passed through the machine
Conveyor Speed 0.2m/s Verify Physically Make a marker on the middle of the belt ,then use the stopwatch test the minute distance then caulate the Second length
Conveyor Height 300 mm Verify Physically Through measuring tape
Max Load 200 Kg(evenly Distributed Verify Physically Put the load equivalent to 200 kg and let it pass through the mechine
Resolution 38 AWG/40 AWG Verify Physically You can cut one of the wire to check this
Steel Penetration 30/38 mm Use an organic things put into a 30mm plate then screen it, try to see if can screen the organic product in orange color
X-ray leakages Less than 1µ Gy/hr (at a distance of 5cm from the housing), complying with all published international standards Use a length 300mm,width300mm,height 75mm board to through the x ray machine ,Then watch the screen
Dose per inspection Less than 1 µ Sv Physically by functioning machine

Film Safety

Guaranteed for high speed film up to ASA/ISP 1600 Use Use the ISO 1600 Film through
X RAY GENERATOR
Anode Voltage 160 K.v. Electrical test method and Procedure.

160 kV

Operating at

150kV

Anode Current 1ma

Electrical test method and

Procedure.

Use Power meter
Cooling Sealed oil bath Test Method and Procedure.

Sealed Di-

Electric Oil

Bath with

Forced Air

Duty Cycle 100% Test Method and Procedure.

Rated for

100% Duty

Cycle

IMAGE ACQUISITION SYSTEM
X Ray Converter L Shaped detector Line Physically by functioning machine
Image Processing 24 bits Physically by functioning machine
Image Storage Capacity Up to 50,000 images Physically by functioning machine
Image Display Color, Black& White, Multi energy, Multi absorptivity, inorganic stripping, Super enhancement, negative, high/low penetration Observe the output
Region of interest(ROI) and Zoom Selectable image, zoom regions,-1-32 times continuous enlargement, 1-3 times local enlargement Physically by functioning machine
Image Recall Preceding image recallable Physically by functioning machine
Display Monitor 17” high resolution D Physically by functioning machine
ADDITIONAL FUNCTIONS
Standard Functions System menu, power on self test, dates/time display, luggage counter, certified number of operators, mains record. System On/Ray on timer, operating mode display, image storage Physically by functioning machine
Optional Explosives/Drugs Detection, Sound Alarm, Light alarm, image pic up system(CIS) Physically by functioning machine
Installation Data
Storage Temperature/Humidity

-40 ° C to + 60 ° C

5% ~95%(Non Condensing)

Non-functional

-40 ° C to + 60 ° C

5% ~95%

Operating temperature/Humidity

0 ° to + 40 °

5% ~95%(Non Condensing)

Functional

0 ° to + 40 °

5% ~95%

Power supply 110-240 VAC(+10% to 15% and 50 Hz/60 Hz (+/- 3 Hz) Functional 110-240 VAC(+10% to 15% and 50 Hz/60 Hz (+/- 3 Hz)
Power Consumption 1.0 KVA Functional 1.0 KVA