General Specification
Tunnel Size: 1000(W)*1000(H)mm
Conveyor Speed.......0.22m/s
Conveyor Max Load:270kg
Dose per Inspection< 1.6μGy/h
Resolution< 0.0787mm Copper Wire
Spatial resolution Level: dia1.3mm, Vertical:dia1.0mm
Penetrate resolution Dia 0.511mm
Penetration40mm Steel
Film Safety:Guarantee ISO1600 Film
X-ray Leakage<0.1μGy/h (at a distance of 5cm From external housing)
X-ray Generator
Generate direct: Bottom to up
Generate anger: 80 degree
Anode Voltage140~160Kv
Anode power0.4 to 1.2mA
Cooling / Duty Cycle Oil Cooling /100%
Image System
X-ray Sensor L-Shaped Photodiode Array (multi-energetic) , 12bit Deep
Monitor High Resolution Color, D Accord, 17 inch
Image Processing Edge enhancement, image strengthening, image lightening,, reducing darkening, image returning, image retrieval.
Image Grey Level4096
Image Max Resolution:1024 * 1280 pixel
Image Processing24bit for processing real time
Image Storage :60000 pictures in real time
Zones & Zoom1-9 Image regions, 2,4,8,16 Times Enlarge, Whole screen continuous observation
Multi-energetic distinguish objects organic objects in orange, inorganic objects in blue, mixture in green
High-energy/low energe: switch from high energy to low energy
Assist to detect drug and explosive powder
Installation Data
Operation temperature/Humidity 0-45/20%-95%(non-condensing)
Storage Temperature/Humidity -20-60/20%-95%(non-condensing)
Operation Power220VAC(±10%)50±3Hz
Power Consumption1.0 KW (max)
Noise: <58db
Tunnel Size: | 1000(W)*1000(H)mm |
Conveyor Speed: | 0.22m/s |
Conveyor Max Load: | 200kgs |
Dose per Inspection: | <1.7μGy/h |
Resolution: | <0.101mm Metal Wire |
Penetration: | 34mm Steel |
Film Safety: | Guarantee ISO1600 Film |
X-ray Leakage: | <0.1μGy/h (at a distance of 5cm From external housing) |
Generate direct: | downward |
Generate angle: | 80 degree |
Anode Voltage: | 100-160Kv |
Anode power: | 0.4 to 1.2mA |
Cooling / Duty Cycle: | Oil Cooling /100% |
X-ray Sensor: | L-Shaped Photodiode Array (mono-energetic), 12bit Deep |
Monitor: | High Resolution Color, D Accord, 17 inch |
Image Processing: | Edge enhancement, image strengthening, image lightening, reducing darkening, image returning, image retrieval. |
Image Grey Level: | 4096 |
Image Max Resolution: | 1024 * 1280 pixel |
Image Processing: | 24bit for processing real time |
Image storage: | Storage 60000 pictures in real time |
Zones & Zoom: | 1-9 Image regions, 2, 4, 8, 16 Times Enlarge, Whole screen continuous observation |
Operation temperature/Humidity: | 0℃-45℃/20%-95%(non-condensing) |
Storage Temperature/Humidity: | -20℃-60℃/20%-95%(non-condensing) |
Operation Power: | 220VAC(±10%)50±3Hz |
Power Consumption: | 1.8 KW (max), 0.3KW(working) |
Noise: | <58db |
Applications:
Airports,
Transport terminals,
Buildings,
Factories (to find needle in clothing, shoes, bags),
Courthouses,
Embassies,
Military installations,
Prisons,
Hotels,
Schools ,
Convention centers,
Security checkpoints,
Special events location
FAQ
.
PRODUCT | CLIENT’S REQUIREMENT | |||
Tunnel Dimension | 1m(W) x 1m(H0 Approx |
Verify Physically
| Measure through measuring tape or a baggage of this dimension should be passed through the machine | |
Conveyor Speed | 0.2m/s | Verify Physically | Make a marker on the middle of the belt ,then use the stopwatch test the minute distance then caulate the Second length | |
Conveyor Height | 300 mm | Verify Physically | Through measuring tape | |
Max Load | 200 Kg(evenly Distributed | Verify Physically | Put the load equivalent to 200 kg and let it pass through the mechine | |
Resolution | 38 AWG/40 AWG | Verify Physically | You can cut one of the wire to check this | |
Steel Penetration | 30/38 mm | Use an organic things put into a 30mm plate then screen it, try to see if can screen the organic product in orange color | ||
X-ray leakages | Less than 1µ Gy/hr (at a distance of 5cm from the housing), complying with all published international standards | Use a length 300mm,width300mm,height 75mm board to through the x ray machine ,Then watch the screen | ||
Dose per inspection | Less than 1 µ Sv | Physically by functioning machine | ||
Film Safety
| Guaranteed for high speed film up to ASA/ISP 1600 | Use Use the ISO 1600 Film through | ||
X RAY GENERATOR | ||||
Anode Voltage | 160 K.v. | Electrical test method and Procedure. | 160 kV Operating at 150kV | |
Anode Current | 1ma | Electrical test method and Procedure. | Use Power meter | |
Cooling | Sealed oil bath | Test Method and Procedure. | Sealed Di- Electric Oil Bath with Forced Air | |
Duty Cycle | 100% | Test Method and Procedure. | Rated for 100% Duty Cycle | |
IMAGE ACQUISITION SYSTEM | ||||
X Ray Converter | L Shaped detector Line | Physically by functioning machine | ||
Image Processing | 24 bits | Physically by functioning machine | ||
Image Storage Capacity | Up to 50,000 images | Physically by functioning machine | ||
Image Display | Color, Black& White, Multi energy, Multi absorptivity, inorganic stripping, Super enhancement, negative, high/low penetration | Observe the output | ||
Region of interest(ROI) and Zoom | Selectable image, zoom regions,-1-32 times continuous enlargement, 1-3 times local enlargement | Physically by functioning machine | ||
Image Recall | Preceding image recallable | Physically by functioning machine | ||
Display Monitor | 17” high resolution D | Physically by functioning machine | ||
ADDITIONAL FUNCTIONS | ||||
Standard Functions | System menu, power on self test, dates/time display, luggage counter, certified number of operators, mains record. System On/Ray on timer, operating mode display, image storage | Physically by functioning machine | ||
Optional | Explosives/Drugs Detection, Sound Alarm, Light alarm, image pic up system(CIS) | Physically by functioning machine | ||
Installation Data | ||||
Storage Temperature/Humidity | -40 ° C to + 60 ° C 5% ~95%(Non Condensing) | Non-functional | -40 ° C to + 60 ° C 5% ~95% | |
Operating temperature/Humidity | 0 ° to + 40 ° 5% ~95%(Non Condensing) | Functional | 0 ° to + 40 ° 5% ~95% | |
Power supply | 110-240 VAC(+10% to 15% and 50 Hz/60 Hz (+/- 3 Hz) | Functional | 110-240 VAC(+10% to 15% and 50 Hz/60 Hz (+/- 3 Hz) | |
Power Consumption | 1.0 KVA | Functional | 1.0 KVA |